Description
Summary: Currently, the rule engine triggers an action the exact moment a condition is met (e.g., Value > Threshold). We need to add a time-based factor to define how long a condition must be true before the rule is triggered. This is essential to filter out transient spikes and manage sustained states.
User Story: As a Bitcoin miner operator, I want my miners to run exclusively on surplus energy. I need to set a rule that turns off the miner if the system draws power from the battery or the grid for more than X minutes, ensuring that short-term power spikes (e.g., a 30-second cloud or a boiler starting) don't trigger an immediate shutdown, while sustained deficits do.
Current Behavior:
- Rule:
IF Grid_Import_Power > 500W THEN Turn OFF Miner - Result: The miner is turned off immediately, even if the imported power spikes to 501W for just 1 second and then drops back down.
Desired Behavior:
- The user should be able to add a "Duration" parameter to the condition.
- The rule logic should be:
IF Condition IS True FOR [Duration] THEN Action. - If the condition becomes False before the [Duration] elapses, the timer resets and no action is taken.
Technical Requirements:
- Time Format: The input must accept the format HH:MM:SS (Hours:Minutes:Seconds).
- Trigger Persistence: The system must monitor the condition
Value > Thresholdand start a timer. - Action Execution: The action (e.g.,
Switch OFF Miner) must execute only if the timer reaches the defined HH:MM:SS duration without the condition ever becoming False. - Instant Reset: If the power draw drops below the threshold even for a second before the timer expires, the timer must reset to zero (to allow for short, acceptable spikes).
Specific Use Cases for Implementation:
-
Case A (Battery Discharge Prevention):
- Metric: Battery Discharge Power.
- Condition:
> 2500W. - Persistence:
00:02:00. - Action:
Smart Plug / Miner: OFF. - Goal: Protect battery discharge.
-
Case B (Grid Bypass Prevention):
- Metric: Grid Import Power (Enel).
- Condition:
> 100W. - Persistence:
00:05:00. - Action:
Smart Plug / Miner: OFF. - Goal: Minimize electricity costs by ensuring the system doesn't stay connected to the grid longer than necessary during temporary solar gaps.
Benefits:
- System Stability: Prevents "flapping" (continuous switching on and off) during transient cloud coverage or home loads startups.
- Avoid Battery Drain: Mining is only profitable if the energy cost is near zero. Using battery-stored energy (which has a cost per cycle) or grid energy (Enel) makes the operation unprofitable.